A-60 and B-15 describe different marine fire-division classifications. The numbers refer to insulation performance periods in the standard fire test; they should not be read simply as the time a door will keep out fire in every real incident. Choose the rating specified for the opening in the vessel’s approved fire-safety arrangement.
A-60 vs B-15: Insulation and Integrity
- A-60: the insulation criteria apply for 60 minutes. A-class doors are assessed over a minimum 60-minute test duration.
- B-15: the insulation criteria apply for 15 minutes, while the B-class integrity criteria apply over a minimum 30-minute test duration.
Insulation limits temperature rise on the unexposed face. Integrity assesses the separation against criteria such as flaming, gaps and cotton-pad ignition. These are distinct test measures.
Source: IMO 2010 FTP Code, Resolution MSC.307(88), Annex 1 Part 3, sections 3.1–3.2 and Appendix 1 section 8.5. Use the applicable amended requirements and the product approval documents for the project.
Which Rating Does Your Vessel Need?
Start with the approved boundary rating and door schedule. A room name alone—such as cabin, corridor, galley or machinery space—is not enough to select a door. Ask the responsible designer, class or flag team to confirm the required rating and installation arrangement for each opening.
Do not treat a higher number as an automatic replacement approval. The surrounding division, frame, hardware and installation details also need to be coordinated. Fire performance and watertight or weathertight performance are separate requirements.
Documents to Check Before Ordering
Request documents for the actual proposed model and configuration. IMO explains that it does not itself test or approve marine products; approval is the responsibility of the relevant national maritime Administration. See IMO’s product-approval explanation.
For a project review, ask the supplier to identify:
- The door model, manufacturer and available approval documentation.
- The proposed leaf and frame arrangement, dimensions and opening direction.
- Hardware, closers, locks, glazing or other options included in the quotation.
- Installation drawings and the interface with the surrounding wall or bulkhead.
- Any differences between the requested configuration and the documented product scope.
Prepare an A-60 or B-15 Door Enquiry
| RFQ item | What to provide |
|---|---|
| Door schedule | Location reference, required rating, quantity, clear opening size, opening direction and finish for each door |
| Boundary and hardware | Wall or bulkhead construction, frame fixing details, closers, locks, glazing and access-control requirements |
| Document requirements | Class or flag requirements, proposed-model approvals, installation drawings and any requested inspection records |
| Delivery and scope | Destination country and port, required delivery date, supply boundaries and coordination requirements |
Show any acoustic, watertight or weathertight requirements separately on the schedule. Confirm the proposed configuration and document scope before ordering.
Send your door schedule for package review. Email drawings to [email protected].
Coordinate marine doors and windows with the wall and ceiling package and marine insulation. See how we coordinate project supply for the wider package workflow.
Frequently Asked Questions
Does B-15 mean only 15 minutes of integrity?
No. The 15-minute insulation period is distinct from the 30-minute minimum B-class test duration described above.
Can I select a fire door by material or thickness?
Use the required classification and the documented door assembly. Material names and thickness alone do not identify an approved configuration.
Can an A-60 door replace a B-15 door?
Any substitution needs project review. Confirm the opening, surrounding division, weight, operating arrangements and approval scope before ordering.
How often should a marine fire door be inspected?
Follow the vessel’s applicable inspection and maintenance programme and the manufacturer’s instructions. This comparison does not establish a universal inspection interval.
Send your fire door schedule for a project quotation. JULY MARINE can review the requested supply scope and available product documentation with your team.